Skip to content
Xian Overseas logoXIAN OVERSEASHeating · Ventilation · Cooling
Indoor Air Quality Practice

The Xian IAQ Lab

Measure the air. Then engineer it.

The Xian IAQ Lab is our dedicated indoor air quality practice — instrumented audits, data-backed diagnosis and engineered remediation for homes, offices, schools, hospitals and industrial spaces across the NCR.

Indoor air quality measurement and air purification
Measured, not guessed

Calibrated monitoring across a full working cycle

Why an IAQ Lab

An air quality complaint is usually a design problem

Most air quality complaints are not a filter problem — they are a design problem. Our engineers measure what a space is actually doing across a working day, model the fresh-air and filtration it needs, and then deliver the fix as an HVAC scope: ventilation rates, filtration stages, humidity control and controls logic, commissioned and verified against the same instruments we started with.

  • A written IAQ report with logged data, not a single spot reading
  • Benchmarks against ASHRAE 62.1, NBC and WHO guidance
  • Root-cause diagnosis tied to your actual HVAC system
  • A costed remediation scope you are free to tender elsewhere
  • Post-commissioning re-measurement to prove the fix worked
  • Optional continuous monitoring with periodic reviews
What We Measure

Eight parameters that decide how a building feels

Each one is logged over time and read together — a single number in isolation rarely tells you what to fix.

PM2.5 / PM10

Particulate Matter

Fine dust that reaches the lungs — the headline pollutant in North Indian winters.

CO₂

Carbon Dioxide

The clearest proxy for under-ventilation, drowsiness and lost concentration in occupied rooms.

CO

Carbon Monoxide

Life-safety critical in basements, car parks and spaces near combustion.

TVOC

Volatile Organic Compounds

Off-gassing from paints, adhesives, furnishings and cleaning agents.

HCHO

Formaldehyde

Common in newly fitted-out interiors and engineered wood.

°C / %RH

Temperature & Humidity

Comfort, condensation risk and mould growth all trace back to these two.

CFM / ACH

Fresh Air & Air Changes

Measured supply against code and occupancy — the number most buildings get wrong.

Pa

Airflow & Pressure Balance

Room-to-room pressurisation that decides where contaminated air actually travels.

How an Audit Runs

From walkthrough to verified air

A structured six-step engagement — you can stop after the report, or have us deliver the fix end to end.

01

Walkthrough & Brief

We map the space, occupancy pattern, existing HVAC and the specific complaints being reported.

02

Instrumented Audit

Calibrated monitors log every key parameter across a full working cycle — not a single spot reading.

03

Diagnosis & Report

A written report benchmarking your air against ASHRAE 62.1, NBC and WHO guidance, with the root cause named.

04

Engineered Remediation

Fresh-air, filtration, humidity and controls designed as a costed HVAC scope — not a product upsell.

05

Execution

Our own installation teams deliver the scope, with minimal disruption to an occupied building.

06

Verification & Monitoring

We re-measure after commissioning and can leave continuous monitoring in place to prove it holds.

The Remediation Toolkit

What we actually install once the data is in

Every recommendation is an engineered HVAC scope our own teams can design, deliver and maintain.

Treated Fresh Air

TFA units and outdoor-air handling sized to real occupancy, so ventilation does not come at the cost of the cooling load.

Energy & Heat Recovery

ERV / HRV systems that bring in outside air while recovering most of the energy you already paid for.

Multi-Stage Filtration

Pre-filters, fine filters and HEPA stages selected for the particulate load your building actually sees.

Humidity Control

Dehumidification and desiccant systems that hold RH in the band where mould and discomfort both stop.

Air Purification & UVGI

In-duct purification and ultraviolet germicidal stages for healthcare, labs and high-density interiors.

Demand-Based Controls

CO₂- and CO-driven ventilation control that ventilates when the building needs it and saves energy when it does not.

Where It Applies

Spaces we audit

Fifty years of HVAC execution across North India means we have usually seen your building type before.

Homes & Residences

Nurseries, bedrooms and closed apartments where winter PM2.5 and low fresh air are the usual culprits.

Offices & Workplaces

CO₂ build-up, afternoon drowsiness and complaints that survive every thermostat change.

Schools & Institutions

High-density classrooms where ventilation drives both health and measurable concentration.

Hospitals & Clinics

Pressurisation, filtration and air-change regimes engineered to clinical requirements.

Retail & Hospitality

Kitchens, lobbies and banquet spaces where odour transfer and make-up air need balancing.

Industrial Spaces

Process exhaust, fume capture and basement CO control audited against life-safety codes.

Start With a Measurement

Find out what your air is really doing

Tell us the space, its size and what you have been noticing. Our engineers will scope an audit and share a timeline — reports typically follow within a week of monitoring.

Let’s design comfort that feels effortless.

Share your project — residential, commercial or industrial — and our engineers will map the right HVAC solution for you.